This page was exported from Free valid test braindumps [ http://free.validbraindumps.com ] Export date:Sat Apr 5 6:14:58 2025 / +0000 GMT ___________________________________________________ Title: [Q12-Q28] Valid NS0-593 Practice Test Dumps with 100% Passing Guarantee [Nov-2023] --------------------------------------------------- Valid NS0-593 Practice Test Dumps with 100% Passing Guarantee [Nov-2023] NS0-593 PDF Dumps Are Helpful To produce Your Dreams Correct QA's Network Appliance NS0-593 exam is a certification exam designed for those who want to become NetApp Certified Support Engineer ONTAP Specialists. It is a comprehensive exam that tests the candidate's knowledge and skills in dealing with various NetApp products, including ONTAP software and hardware platforms. Passing NS0-593 exam is a requirement for those who want to advance their careers in the field of storage and data management. Network Appliance NS0-593 certification exam is an important step for IT professionals who specialize in NetApp ONTAP support. NetApp Certified Support Engineer ONTAP Specialist certification exam is designed to test the skills and knowledge of candidates in a variety of areas related to NetApp storage systems, including architecture, data management, and troubleshooting. By earning the NetApp Certified Support Engineer ONTAP Specialist certification, IT professionals can demonstrate their expertise in this field and advance their careers in the IT industry.   NEW QUESTION 12Referring to the exhibit, from which delay center is most of the latency for voll?  Disk  Network  Data  NVRAM NEW QUESTION 13You ate connecting a Windows Server 2019 hostto ISCSI LUNs on a 4-node AFF A250 cluster runningNetApp ONIAP 9.8 software. The host is unable to connect to the target interface, and the ONTAP event loghas the message shown below.ISCSI: network interface identifier disabled for use; incoming connection discardedIn this scenario, what is the cause of this connection issue?  iSNS is not enabled on the storage virtual machine.  The WWPN was not added to the initiator group.  The iSCSI service is not enabled on the interface.  CHAP isnot configured correctly for the specified initiator. NEW QUESTION 14The motherboard of Node-01 is being replaced. To perform this task, a takeover was Initiated from Node-02.Node-02 panics showing the string below.PANIC; Permanent errors on all HA mailbox disks (while marshalling header) in SKprocessfnmbx_instanceWorker on release 9.5P8 (C)What has happened in this situation?  While in maintenance mode, the sldiag device show command was executed.  While in maintenance mode, the fcadmin device_map command was executed.  While in maintenance mode, the HA_config show command was executed.  While in maintenance mode, the mailbox destroy local command was executed. NEW QUESTION 15Your customer complains that u host will constantly report losing a connection to the iSCSl target and thenreport that the session was reestablished.As shown in the exhibit, what is a cause of this flapping?  A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 have thesame IQN.  A host with an IP address of 172.20.10.80 and a secondhost with an IP address of 10.10.20.60 are indifferent initiator groups.  A host with an IP address of 172.20.10.80 and a second host with an IP address of 10.10.20.60 areaccessing the same LUN.  A host with an IP address of 172.20.10.80 and a secondIP address of 10.10.20.60 is accessing different LUNs. NEW QUESTION 16A storage administrator reports that a monitoring toot is reporting that the storage controller reads between90% to 93% CPU use. You run the sysstat -m command against thenode in question.Referring to the exhibit, which statement is correct?  The customer should be advised to exclude certain workflows to reduce use.  High network exempt use could be a problem.  You should immediately investigate further bygathering perfstat data and opening a support case.  The CPU Is not a first-order monitoring metric for ONTAP. NEW QUESTION 17Your customer calls you because one application is not able to access a NetApp ONTAP S3 bucket. Whilereviewing the EMS log on the cluster, you see the following message:The same credentials work in another application.In this scenario, what would cause this problem?  The application is trying to log in as an anonymous user.  The application is using v2 signatures.  The application is using v4 signatures.  The application is trying to access using the HTTP protocol. NEW QUESTION 18Your customer Informs you about SnapMlrror problems after upgrading NetApp ONTAP software to a newerversion. After investigating the event logs and the SnapMirror history, you see information about delayedupdates of the SnapMirror relationships.How would your customer prevent such problems in the future?  Quiesce the SnapMirror relationships before upgrading the ONTAP software.  Verify that the cabling of the hardware port that Is responsible for SnapMirror transfers Is correct.  Modify the schedules of the SnapMirror relationships after upgrading the ONTAP software.  Delete the SnapMirror relationships and create them new after upgrading the ONTAP software. NEW QUESTION 19You receive the panic message shown in the exhibit.In this scenario, which component should you troubleshoot first?  the PCI card in slot 3  the MetroCluster FC-Vl card in slot 6  the memory module in slot 1  the CPU NEW QUESTION 20A customer with an FC MetroClusterconfiguration that is running NetApp ONTAP 9.8 software experienced asite outage and wants to know why the MetroClusler configuration did not switch over to the other site.What are two reasons for this problem? (Choose two.)  There was a failed PSU inthe switchover site.  The ISLs were down between the sites.  The site had unmirrored aggregates.  An ISL link was not operating at 16Gbps. NEW QUESTION 21After a normal power down of both nodes forbuilding maintenance, Node01 of a 2-node cluster cannot bepowered back up; however, all disk shelves are powered.Which action should be performed to bring the cluster online and allow Node02 to serve data?  Recreate the cluster with the system configuration recovery cluster recreate -from node command.  Reboot the node With the system node reboot -node Node02 -bypass-optimization true command.  Perform a takeover with the storage failover takeover -ofnode Node01 -option forcecommand.  Reinitialize the cluster with option 4a from the boot menu. NEW QUESTION 22You have a 2-node NetApp FAS2750 switchless cluster with twenty-four 1.8 TB disks that is experiencingperformance issues. Upon investigation, you discover severaltype B consistency points.Referring to the exhibit, which corrective action would address these consistency points?  Create additional data LIFs.  Convert the 2-node switchless cluster to a 2-node switched cluster.  Add an additional shelf oftwenty-four 1.8 TB disks.  Replace the twenty-four 1.8 TB disks with twelve 4 TB disks. NEW QUESTION 23Which two throughput elements are controlled by host applications? (Choose two.)  operation size  Jitter  concurrency  latency NEW QUESTION 24You want to assign storage access to an NVMe protocol host.Which three objects must beconfigured to accomplish this task? (Choose three.)  the NVMe subsystem  the NVMe broadcast domain  an NVMe LIF  the NVMe namespace  an NVMe LUN NEW QUESTION 25A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40GEthernet card in slot 4 for this purpose. The link comes up fine on node 2,but it will not come up on node 1.You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.What is the cause of the customer’s problem?  The cable is plugged in upside down.  The incorrect cable is used.  The ports are configured for 4x10Gbit instead of 40Gbit.  The port has an incorrect SFP inserted. NEW QUESTION 26Which two statements about NetApp Cloud Volumes ONTAP licenses ate true? (Choose two.)  Having an Essentials package enables you to convert to another licensing option.  Capacity-based license packages support only single-node configurations.  BYOL licenses are purchased directly from NetApp.  AWS Marketplace contracts cannot be mixed with BYOL. NEW QUESTION 27You have a new VMware vSphere cluster with ESXI 7.0U2 hosts. The hosts are connected to a 4-node AFFA400 NetApp ONTAP9.8 cluster with FC LUNs. You have a requirement to identify and follow I/Os fromeach VM on the shared FC LUN-backed datastores for troubleshooting purposes.In this scenario, which VMware feature Is supported by ONTAP software to accomplish this task?  Network I/O Control (NIOC)  Virtual machine ID (VMID)  Storage I/O Control (SIOC)  vSphere Cluster Services (vCLS) NEW QUESTION 28Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FCprotocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reportsthat the server’s FC HBA port Is online, but the LUN does not show up.Referring to the exhibit, what is the reason for this problem?  The FC service has not been configured on the SVM.  The zoning on the FC switches Is Incorrect.  The LUN Is not mapped to the correct SCSI ID.  The esxserver igroup contains incorrect IQNs.  Loading … Cover NS0-593 Exam Questions Make Sure You 100% Pass: https://www.validbraindumps.com/NS0-593-exam-prep.html --------------------------------------------------- Images: https://free.validbraindumps.com/wp-content/plugins/watu/loading.gif https://free.validbraindumps.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2023-11-30 12:50:37 Post date GMT: 2023-11-30 12:50:37 Post modified date: 2023-11-30 12:50:37 Post modified date GMT: 2023-11-30 12:50:37